The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
park place pavers
(914)667-1735
255 rich ave
mount vernon, NY
Maduri Steven Masonry Corp
(914) 948-9678
706 Mamaroneck Ave
White Plains, NY
L A Sesto Constr Corp
(631) 243-1818
80 Jefferson Ave
Bay Shore, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Peter Home Improvements Corp
(718) 699-8441
5841 Waldron St
Flushing, NY
Academic Stone Setters Inc
(718) 463-7395
2907 119th St
Flushing, NY
Green Lawn Garden Center
(914) 682-4848
454 Ridgeway
White Plains, NY
Hull Construction and Restoration
(914) 220-0111
230 Ferris Ave
White Plains, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Hitachi KM 12VC Router Combination Kit White Plains NY
Sometimes combination tools have to make too many compromises to perform their numerous functions. Fortunately, that's not the case with Hitachi's new KM 12VC router combination kit. This smartly designed, solidly constructed, and well-outfitted tool fulfills its promises as a fixed-base and plunge-base router. And, at $180 you've got a tool that pulls its weight without asking much in return.
- How Masonry Buildings Resist Earthquakes White Plains NY
- Home Siding Tips White Plains NY
- Drape Wall and Cloak Wall White Plains NY
- Flashing Factors White Plains NY
- Guidelines for Assembling Scaffolding White Plains NY
- Galvanized Wall Ties White Plains NY
- High-Efficiency Products White Plains NY
- Galvanized Wall Ties White Plains NY
- Flashing in Siding Installations White Plains NY