The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Franklin Stucco Of Jamaica Inc
(718) 523-0099
14815 Liberty Ave
Jamaica, NY
Agl Land Design Inc
(631) 673-2854
19 Duncan Ln
Huntington, NY
Fort Hill Landscape And Design Inc
(631) 271-8651
151 New York Ave
Huntington, NY
SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Hatiya Contracting Inc
718-395-7744
9322 74th Place
Woodhaven, NY
Alpha Design Corp
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY
Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Wantagh NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Galvanized Wall Ties Wantagh NY
- Hitachi KM 12VC Router Combination Kit Wantagh NY
- Drape Wall and Cloak Wall Wantagh NY
- Guidelines for Assembling Scaffolding Wantagh NY
- Flashing Factors Wantagh NY
- Galvanized Wall Ties Wantagh NY
- Flashing in Siding Installations Wantagh NY
- Home Siding Tips Wantagh NY
- How Masonry Buildings Resist Earthquakes Wantagh NY