Inner Corner at Base of Wall Suffern NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Omni Landscaping Inc
(845) 357-3001
12 Colline Dr
Suffern, NY
Carmody Building Corp
(845) 352-2299
145 College Rd
Suffern, NY
M-N-M Contractors
(914) 736-1546
2 John Walsh Blvd
Peekskill, NY
D & F Mason Inc
(718) 324-6647
4418 Bronx Blvd
Bronx, NY
Alves Construction Corp
(516) 777-2100

Massapequa, NY
K B Masonry LLC
(973) 831-0018
58 Townsend Road
Wanaque, NJ
AAA Paving
(845) 357-0803

Suffern, NY
Yurewich Victor
(845) 354-1362
75 Wilder Rd
Suffern, NY
Jc Concrete Inc
(631) 736-9528
72 Abner Dr
Farmingville, NY
Casler Masonry Incorporated
(607) 642-5136

Newark Valley, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips Suffern NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- Flashing in Siding Installations Suffern NY
- Flashing Factors Suffern NY
- How Masonry Buildings Resist Earthquakes Suffern NY
- Hitachi KM 12VC Router Combination Kit Suffern NY
- High-Efficiency Products Suffern NY
- Galvanized Wall Ties Suffern NY
- Drape Wall and Cloak Wall Suffern NY
- Guidelines for Assembling Scaffolding Suffern NY
- Galvanized Wall Ties Suffern NY