Inner Corner at Base of Wall Richmond Hill NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Ventura Masonry
(908) 289-0658
805 E Jersey St
Elizabeth, NJ
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
TONYS MASONRY
(917) 402-5202
262 wilson avenue
staten island, NY
Hatiya Contracting Inc
718-395-7744
9322 74th Place
Woodhaven, NY
Drew Masonry
(908) 289-4024
17 James Ave
Elizabeth, NJ
Samson Stone Co Inc
(201) 656-2417
1000 Newark Ave
Jersey City, NJ
Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY
park place pavers
(914)667-1735
255 rich ave
mount vernon, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Hitachi KM 12VC Router Combination Kit Richmond Hill NY
Sometimes combination tools have to make too many compromises to perform their numerous functions. Fortunately, that's not the case with Hitachi's new KM 12VC router combination kit. This smartly designed, solidly constructed, and well-outfitted tool fulfills its promises as a fixed-base and plunge-base router. And, at $180 you've got a tool that pulls its weight without asking much in return.
- Home Siding Tips Richmond Hill NY
- Flashing in Siding Installations Richmond Hill NY
- Galvanized Wall Ties Richmond Hill NY
- High-Efficiency Products Richmond Hill NY
- How Masonry Buildings Resist Earthquakes Richmond Hill NY
- Drape Wall and Cloak Wall Richmond Hill NY
- Galvanized Wall Ties Richmond Hill NY
- Flashing Factors Richmond Hill NY
- Guidelines for Assembling Scaffolding Richmond Hill NY