The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

K B Masonry LLC
(973) 831-0018
58 Townsend Road
Wanaque, NJ
Bowen B Mason Jr Rl Est
(716) 849-1234
560 Delaware Ave
Buffalo, NY
Mc Gowan James Masonry
(845) 339-0329
5 Railroad Ave
Kingston, NY
M Peter Construction Corp
(516) 735-1540
2307 Legion St
Bellmore, NY
3Z Masonary Inc
(845) 386-1393
36 Valley View Rd
Otisville, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
park place pavers
(914)667-1735
255 rich ave
mount vernon, NY
182 Brady Llc
(845) 386-2694

Middletown, NY
Superior Mason Contracting Inc
(631) 667-5404
1123 Carlls Straight Path
Dix Hills, NY
Parrelli Masonry
(914) 835-2378
43 2nd St
Harrison, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Hitachi KM 12VC Router Combination Kit Pearl River NY
Sometimes combination tools have to make too many compromises to perform their numerous functions. Fortunately, that's not the case with Hitachi's new KM 12VC router combination kit. This smartly designed, solidly constructed, and well-outfitted tool fulfills its promises as a fixed-base and plunge-base router. And, at $180 you've got a tool that pulls its weight without asking much in return.
- Flashing in Siding Installations Pearl River NY
- Drape Wall and Cloak Wall Pearl River NY
- Galvanized Wall Ties Pearl River NY
- Galvanized Wall Ties Pearl River NY
- Home Siding Tips Pearl River NY
- High-Efficiency Products Pearl River NY
- How Masonry Buildings Resist Earthquakes Pearl River NY
- Flashing Factors Pearl River NY
- Guidelines for Assembling Scaffolding Pearl River NY