Inner Corner at Base of Wall New York NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

S & A Contractors
(908) 354-9557
207 Shelley Ave
Elizabeth, NJ
Rapid Masonry Restoration
(718) 424-8304
7906 37th Ave
Jackson Heights, NY
Anton Haddad Plumbing & Heating
(201) 792-1587
15 Saddlewood Ct
Jersey City, NJ
Willow Snow Removal
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Ventura Masonry
(908) 289-0658
805 E Jersey St
Elizabeth, NJ
Ugolini Elio Mason Contractor
(201) 433-4304
213 Harrison Ave
Jersey City, NJ
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations New York NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- How Masonry Buildings Resist Earthquakes New York NY
- High-Efficiency Products New York NY
- Hitachi KM 12VC Router Combination Kit New York NY
- Drape Wall and Cloak Wall New York NY
- Galvanized Wall Ties New York NY
- Flashing Factors New York NY
- Galvanized Wall Ties New York NY
- Guidelines for Assembling Scaffolding New York NY
- Home Siding Tips New York NY