The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Rapid Masonry Restoration
(718) 424-8304
7906 37th Ave
Jackson Heights, NY
Jameson Mark
(201) 386-1500
Hoboken Area
Jersey City, NJ
Agl Land Design Inc
(631) 673-2854
19 Duncan Ln
Huntington, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
park place pavers
(914)667-1735
255 rich ave
mount vernon, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY
Academic Stone Setters Inc
(718) 463-7395
2907 119th St
Flushing, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips New Rochelle NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- Galvanized Wall Ties New Rochelle NY
- Flashing in Siding Installations New Rochelle NY
- How Masonry Buildings Resist Earthquakes New Rochelle NY
- Guidelines for Assembling Scaffolding New Rochelle NY
- Galvanized Wall Ties New Rochelle NY
- Hitachi KM 12VC Router Combination Kit New Rochelle NY
- High-Efficiency Products New Rochelle NY
- Flashing Factors New Rochelle NY
- Drape Wall and Cloak Wall New Rochelle NY