Inner Corner at Base of Wall New Hartford NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Structure Tek Masonry Division
(516) 799-2300
5394 Merrick Rd
Massapequa, NY
G & L Custom Brick Work
(718) 931-8297
937 Pierce Ave
Bronx, NY
Mendes Painting & Decorating
(845) 364-9762
8 Chamberlain Ct
Pomona, NY
Stonecretes Masonry Corp
(631) 736-5628
1305 Middle Country Rd
Selden, NY
Brookfield Maintenance
(631) 789-3955
23 Grand Ave
Farmingdale, NY
Masonry Stoneledge
(315) 733-7243
4067 State Route 12
New Hartford, NY
Sam's Masonry
(914) 964-6859
414 Warburton Ave
Yonkers, NY
Brooklyn Mason Supply Co Inc
(718) 421-0900
1593 Albany Ave
Brooklyn, NY
Oak Hill Constr Corp
(631) 422-6144
500 Lexington Ave
West Babylon, NY
Westchester Brickpaving Inc
(914) 337-0849
203 Leetown Rd
Stormville, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations New Hartford NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- How Masonry Buildings Resist Earthquakes New Hartford NY
- Hitachi KM 12VC Router Combination Kit New Hartford NY
- Flashing Factors New Hartford NY
- Drape Wall and Cloak Wall New Hartford NY
- Galvanized Wall Ties New Hartford NY
- Guidelines for Assembling Scaffolding New Hartford NY
- High-Efficiency Products New Hartford NY
- Home Siding Tips New Hartford NY
- Galvanized Wall Ties New Hartford NY