Inner Corner at Base of Wall New City NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

park place pavers
(914)667-1735
255 rich ave
mount vernon, NY
O'hara's
(845) 634-5299

New City, NY
Trulys Contracting Corp
(631) 218-8238
186 Locust Ave
Oakdale, NY
Syrbescapes
(631) 361-6978
246 Alexander Ave
Nesconset, NY
Emerald Isle Masonry
(631) 218-2510
980 Montauk Hwy
Oakdale, NY
K B Masonry LLC
(973) 831-0018
58 Townsend Road
Wanaque, NJ
Hill Josef Masonry
(845) 638-6964
8 Acorn Ter
New City, NY
Mid Island Masonary
(631) 969-9724
1 Avon Pl
Bay Shore, NY
Atm
(631) 476-4332
Route 25A
Port Jefferson Station, NY
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Guidelines for Assembling Scaffolding New City NY
Frame scaffolding, made from welded steel tubing (also called "pipe staging") is only safe if it is erected properly. Once the staging is erected with the proper planks, it should be like standing on a floor —which will make your crew more comfortable and safe.
- Drape Wall and Cloak Wall New City NY
- Flashing in Siding Installations New City NY
- Home Siding Tips New City NY
- Flashing Factors New City NY
- High-Efficiency Products New City NY
- Galvanized Wall Ties New City NY
- How Masonry Buildings Resist Earthquakes New City NY
- Hitachi KM 12VC Router Combination Kit New City NY
- Galvanized Wall Ties New City NY