Inner Corner at Base of Wall Mount Vernon NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Samson Stone Co Inc
(201) 656-2417
1000 Newark Ave
Jersey City, NJ
Malatesta Paladino Inc
(718) 523-5656
13919 109th Ave
Jamaica, NY
Sanyo Enterprises Usa Inc
(718) 846-8100
11617 Sutphin Blvd
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Jameson Mark
(201) 386-1500
Hoboken Area
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Alpha Design Corp
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Peter Home Improvements Corp
(718) 699-8441
5841 Waldron St
Flushing, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Mount Vernon NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Flashing in Siding Installations Mount Vernon NY
- Home Siding Tips Mount Vernon NY
- Galvanized Wall Ties Mount Vernon NY
- Hitachi KM 12VC Router Combination Kit Mount Vernon NY
- Galvanized Wall Ties Mount Vernon NY
- Drape Wall and Cloak Wall Mount Vernon NY
- How Masonry Buildings Resist Earthquakes Mount Vernon NY
- Guidelines for Assembling Scaffolding Mount Vernon NY
- Flashing Factors Mount Vernon NY