Inner Corner at Base of Wall Hempstead NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Malatesta Paladino Inc
(718) 523-5656
13919 109th Ave
Jamaica, NY
Alpha Design Corp
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY
Sanyo Enterprises Usa Inc
(718) 846-8100
11617 Sutphin Blvd
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Agl Land Design Inc
(631) 673-2854
19 Duncan Ln
Huntington, NY
Capstone Construction
(631) 784-7701
775 Park Ave
Huntington, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Hempstead NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Flashing Factors Hempstead NY
- Hitachi KM 12VC Router Combination Kit Hempstead NY
- How Masonry Buildings Resist Earthquakes Hempstead NY
- Home Siding Tips Hempstead NY
- Guidelines for Assembling Scaffolding Hempstead NY
- Flashing in Siding Installations Hempstead NY
- Galvanized Wall Ties Hempstead NY
- Drape Wall and Cloak Wall Hempstead NY
- Galvanized Wall Ties Hempstead NY