Inner Corner at Base of Wall Great Neck NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Willow Run Construction
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
Villa Stucco
(201) 653-9447
54 Jefferson Ave
Jersey City, NJ
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Begolli Brother Construction and Restoration
(516) 476-6166
134 maple avenue
westbury, NY
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
Samson Stone Co Inc
(201) 656-2417
1000 Newark Ave
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Flashing in Siding Installations Great Neck NY
A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic.
- Guidelines for Assembling Scaffolding Great Neck NY
- High-Efficiency Products Great Neck NY
- Home Siding Tips Great Neck NY
- Flashing Factors Great Neck NY
- Galvanized Wall Ties Great Neck NY
- Drape Wall and Cloak Wall Great Neck NY
- Hitachi KM 12VC Router Combination Kit Great Neck NY
- Galvanized Wall Ties Great Neck NY
- How Masonry Buildings Resist Earthquakes Great Neck NY