Inner Corner at Base of Wall Elmont NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Jameson Mark
(201) 386-1500
Hoboken Area
Jersey City, NJ
Sanyo Enterprises Usa Inc
(718) 846-8100
11617 Sutphin Blvd
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY
SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
Pezzino Nely
(718) 358-1481
2221 Parsons Blvd
Flushing, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Hitachi KM 12VC Router Combination Kit Elmont NY
Sometimes combination tools have to make too many compromises to perform their numerous functions. Fortunately, that's not the case with Hitachi's new KM 12VC router combination kit. This smartly designed, solidly constructed, and well-outfitted tool fulfills its promises as a fixed-base and plunge-base router. And, at $180 you've got a tool that pulls its weight without asking much in return.
- Galvanized Wall Ties Elmont NY
- High-Efficiency Products Elmont NY
- Home Siding Tips Elmont NY
- How Masonry Buildings Resist Earthquakes Elmont NY
- Flashing in Siding Installations Elmont NY
- Flashing Factors Elmont NY
- Galvanized Wall Ties Elmont NY
- Guidelines for Assembling Scaffolding Elmont NY
- Drape Wall and Cloak Wall Elmont NY