Inner Corner at Base of Wall Dunkirk NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Town Masonry Corp
(914) 779-5100
711 S Columbus Ave
Mount Vernon, NY
R P Prudente Contracting Corp
(516) 333-1777
496 Grand Blvd
Westbury, NY
New York Design General Contractors Inc
(718) 966-2447
48 Marne Ave
Staten Island, NY
Rusty Johnson Masonary Inc
(315) 482-7632
23284 County Route 3
La Fargeville, NY
Gonser Construction Inc
(716) 627-4547
5156 Lake Shore Rd
Hamburg, NY
Gentile Peter Mason Contrctng
(516) 932-5611
134 Broadway
Bethpage, NY
McGowan James
(845) 339-0329
5 Railroad Ave
Kingston, NY
Zarrelli Dante Mason Contractor
(518) 725-4408

Gloversville, NY
Rock-N-Country Stone Mason
(607) 746-7460

Delhi, NY
City View Masonry Corp
(718) 894-0450
5817 59th Dr
Maspeth, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products Dunkirk NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Hitachi KM 12VC Router Combination Kit Dunkirk NY
- Flashing in Siding Installations Dunkirk NY
- Drape Wall and Cloak Wall Dunkirk NY
- How Masonry Buildings Resist Earthquakes Dunkirk NY
- Home Siding Tips Dunkirk NY
- Galvanized Wall Ties Dunkirk NY
- Guidelines for Assembling Scaffolding Dunkirk NY
- Galvanized Wall Ties Dunkirk NY
- Flashing Factors Dunkirk NY