The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Scott Charles A
(845) 358-4646
60 Mountainview Ave
Nyack, NY
Furey Stone Specialties
(518) 789-3175
34 Park St
Millerton, NY
Jacob's Masonry Corp
(718) 645-4858
2569 Stillwell Ave
Brooklyn, NY
Saga House Condominium
(212) 879-2611
157 E 74th St
New York, NY
H M R Masonry Restoration
(718) 931-7233
1437 Bassett Ave
Bronx, NY
Gould Laura
(845) 651-5421
346 Reservoir Rd
Goshen, NY
L A Sesto Constr Corp
(631) 243-1818
80 Jefferson Ave
Bay Shore, NY
Classic Masonry Ltd
(845) 526-8511
110 Kramers Pond Rd
Putnam Valley, NY
Frezza A Contrctng Corp
(516) 746-3508
76 Marcus Ave
New Hyde Park, NY
Consolidated Masonry
(607) 722-0041
19 Alice St
Binghamton, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips Coram NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- Galvanized Wall Ties Coram NY
- Flashing in Siding Installations Coram NY
- Hitachi KM 12VC Router Combination Kit Coram NY
- How Masonry Buildings Resist Earthquakes Coram NY
- Galvanized Wall Ties Coram NY
- Drape Wall and Cloak Wall Coram NY
- Flashing Factors Coram NY
- High-Efficiency Products Coram NY
- Guidelines for Assembling Scaffolding Coram NY