Inner Corner at Base of Wall Beacon NY

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Delcolle John Inc
(631) 423-6383
11 Cager Pl
Huntington Station, NY
Geneva Curb & Concrete Co Inc
(315) 781-1710
64 Seneca St
Geneva, NY
Hudson Masonry
(845) 343-4508

Middletown, NY
Angelo's Construction
(914) 669-5581
16 Guinea Rd
Brewster, NY
Miller's Masonry & More
(518) 494-2321
632 Vanderwalker Rd
Chestertown, NY
Masonry Landscaping & Construction
(845) 897-2050

Beacon, NY
Zabriskie Cornelius Neal
(845) 386-1393
36 Valley View Rd
Otisville, NY
Daponte Constr Corp
(631) 475-3975
17 Sylvan Dr
Holtsville, NY
Walters & Lambert Mason Contractors Inc
(845) 266-4758
323 Hibernia Rd
Salt Point, NY
Hill Josef Masonry
(845) 638-6964
8 Acorn Ter
New City, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips Beacon NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- High-Efficiency Products Beacon NY
- Galvanized Wall Ties Beacon NY
- Flashing in Siding Installations Beacon NY
- Hitachi KM 12VC Router Combination Kit Beacon NY
- Drape Wall and Cloak Wall Beacon NY
- Galvanized Wall Ties Beacon NY
- Guidelines for Assembling Scaffolding Beacon NY
- Flashing Factors Beacon NY
- How Masonry Buildings Resist Earthquakes Beacon NY