The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.

Local Companies

Dbl Masonry
(518) 577-2186
26b College View Dr
Albany, NY
Nys Concrete Masonry Assoc
(518) 464-1806
6 Airline Dr Ste 102
Albany, NY
Chimney Wizards
(518) 427-7603
100 Lark St
Albany, NY
Kneeland Constr Co
(518) 452-7320
25 Corporate Cir Ste 3
Albany, NY
Pcc Contracting Inc
(518) 785-8000
600 Troy Schenectady Rd
Albany, NY
Colonie Masonry Corp Of Albany Inc
(518) 370-2471
1971 Western Ave # 231
Albany, NY
Di Pace Masonry Inc
(518) 459-1834
1 Kneeland St
Albany, NY
Tompkins Masonry Corp
(518) 465-1621
210 Sheridan Ave
Albany, NY
Ipek Z & Sons Inc
(518) 371-2544
7 Railroad Ave
Albany, NY
Mauriello Construction
(518) 283-5321
6 Bentley Ave
Albany, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: September 1, 2006

By Walter A. Laska

It is difficult for a mason to properly tool mortar joints at inner wall corners due to the size and shape of the jointer and the acute angle formed by the intersecting brick. As a result, the mortar joints at this location cannot be tooled neatly or compactly. Therefore, inner wall corners provide an ideal location for expansion joints.

Expansion joints located at inner corners are easy to construct and are well concealed. The expansion joint should be totally void of any material which might inhibit movement, and the reinforcement must be discontinuous at the expansion joint.

The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry. Also, the connection creates a control joint in the concrete masonry backing along the column interface.
Elevation View

The space between the column and the concrete masonry should be kept free of all mortar bridging. If the column and concrete masonry are tightly bonded, any movement of the column is transferred to the masonry, possibly causing the concrete masonry backing to crack.

Flashing continuity must be maintained at the inner corners. The flashing should be cut, lapped, and set in a continuous bed of mastic to prevent water from flowing under the laps.

Click here to read full article from Masonry Construction

Related Articles
- Hitachi KM 12VC Router Combination Kit Albany NY
Sometimes combination tools have to make too many compromises to perform their numerous functions. Fortunately, that's not the case with Hitachi's new KM 12VC router combination kit. This smartly designed, solidly constructed, and well-outfitted tool fulfills its promises as a fixed-base and plunge-base router. And, at $180 you've got a tool that pulls its weight without asking much in return.
- Home Siding Tips Albany NY
- Drape Wall and Cloak Wall Albany NY
- How Masonry Buildings Resist Earthquakes Albany NY
- Flashing Factors Albany NY
- Guidelines for Assembling Scaffolding Albany NY
- Galvanized Wall Ties Albany NY
- High-Efficiency Products Albany NY
- Galvanized Wall Ties Albany NY
- Flashing in Siding Installations Albany NY