Incorrect Testing Practices Syosset NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Syosset. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Dennis Forte Construction, LLC
914-202-8720
53 Lispenard Ave.
Bronxville, NY
Bargain Tile
516-593-3939
430 Sunrise Highway
Lynbrook, NY
junk junkies, junk removal, nyc-stay clutter free, live green!
888-433-4133
229-19 merrick blvd suite345
jamaica, NY
VISCO ASBESTOS REMOVAL
516 547 2510
235 ROBINS LA
SYOSSET, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Elmont glass
516 248 8860
2145 jericho tpke
Garden city park, NY
GLOBAL CONSTRUCTION
914 406 5513
838 MCLEAN AVE
YONKERS, NY
Niwa International
917-929-5369
123-50 Lax Ave.
College Point, NY
JBS WATERPROOFING & ROOFING
(347) 583-5313
1149 white plains rd
bronx, NY
Pro Qualtiy Home Improvements Inc.
631 393 6812
500 Bi-County Blvd.
Farmingdale, NY
Data Provided by:
  

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer

Related Articles
- Festool Circ Saw and Guide Rail System Syosset NY
The TS 75 EQ excels at making precise straight cuts. It's not a framing saw, and it doesn't pretend to be; but this precise saw and guide will change the way you make long clean cuts on site.
- Green Construction Syosset NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details