Incorrect Testing Practices Saugerties NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Saugerties. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Hudson Valley Construction
845 247 0701
10 fawn rd
saugerties, NY
New Paltz Roll Offs, Inc.
(845) 255-4745
PO Box 179
Tillson, NY
AT & T
(845) 331-4600
612 Ulster Avenue
Kingston, NY
Cutting Edge Spray Foam Services, Inc.
845-679-6980
1676 Route 212
Saugerties, NY
Primer Construction Corp
(718) 963-0111
100 Maspeth Ave
Brooklyn, NY
Willin Contracting Inc
845-775-8571
241 MacDaniel Rd
Shady, NY
Cooper & Company
(914) 456-9900
PO Box 344
West Park, NY
Catskill Mountain Stone Work & Landscape Design
(845) 399-1448
24 Albright Lane
Stone Ridge, NY
Mike Mattera Trucking & Crane Ser.
845-706-3085
PO Box 688
Saugerties, NY
Ianniello Bros Inc
(718) 224-0901
6451 214th St
Flushing, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer