Incorrect Testing Practices Riverhead NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Riverhead. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Good Earth Sales
516-818-2746
po box 711
medford, NY
Leonardo J T Masonry
(585) 396-5910

Canandaigua, NY
Decker Contractors Inc
(845) 583-4432
484 Horseshoe Lake Rd
Swan Lake, NY
Hy-Tech Concrete
(716) 778-5499
6136 1st St
Newfane, NY
Rush Concrete Corp
(631) 474-1362
27 Miller Farms Dr
Miller Place, NY
Autumn Masonry
631-828-1687
10 Locust Avenue
Coram, NY
Cross Island Concrete Corp
(631) 369-0579
160 Kroemer Ave
Riverhead, NY
Hilco Constr Co Inc
(516) 775-9662
1824 Gilford Ave
New Hyde Park, NY
Murphy Brothers Contracting
(315) 784-5803
Rowe Rd
Skaneateles, NY
Tc Concrete Inc
(718) 824-1965
185 Swinton Ave
Bronx, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...