Incorrect Testing Practices Plattsburgh NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Plattsburgh. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Corrado Concrete Constr Co
(518) 563-8358
32 Douglaston Dr
Plattsburgh, NY
Corning Concrete Co
(607) 562-3931
11819 E Corning Rd
Corning, NY
Union Concrete
(716) 297-1504
2471 Military Rd
Niagara Falls, NY
Drexler Land Development Corp
(516) 292-8420

Hempstead, NY
O'hara Mason Contractors Llc
(845) 795-1273

Milton, NY
Weather Barrier Construction
(802) 782-6364
24 South Elm Street
Saint Albans, VT
Gateway Industries Inc
(516) 933-7400
390 N Broadway
Jericho, NY
Luca Antonelli Contracting
(718) 423-6368

Flushing, NY
Capital Concrete Inc
(518) 438-2816
107 Van Patten Ln
Albany, NY
C M C Construction
(718) 617-0318
525 Faile St
Bronx, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer