Incorrect Testing Practices Pittsford NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Pittsford. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Professional Finishes
585-533-9140
28 academy dr.
rochester, NY
CO9 STEEL
585 301 7724
310 angelus dr
ROCHESTER, NY
Glenwood Concrete Constr Inc
(718) 434-1967
4415 Glenwood Rd
Brooklyn, NY
Bay Village Paving
(631) 264-2500
65 Oak St
Copiague, NY
Inner City Construction
(718) 525-4400
12501 Merrick Blvd
Jamaica, NY
DJM Equipment
585-223-4056
7216 Palmyra Road
Fairport, NY
LM Sanderson Construction Inc.
585 370 6076
891 Dewitt rd.
Webster, NY
Lusa Concrete Corp
(631) 475-3790
40 Barretts Ave
Holtsville, NY
Tnc Corp
(718) 658-7893
9405 165th St
Jamaica, NY
Barbato & Son
(631) 581-1461
303 Islip Ave
Islip, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer