Incorrect Testing Practices Patchogue NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Patchogue. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

all stone restoration
631 780 5404
po box 115
smithtown ny, NY
Good Earth Sales
516-818-2746
po box 711
medford, NY
Michael McConnell Concrete Inc
(315) 234-8924
3600 Walters Rd
Syracuse, NY
Roman Concrete
(631) 544-4636
150 Townline Rd
Kings Park, NY
Messina Asphalt Corp
(718) 932-2208
1850 42nd St
Astoria, NY
Truckloaders
631-872-2275
West Jericho Tpk
Smithtown, NY
Autumn Masonry
631-828-1687
10 Locust Avenue
Coram, NY
Walkway Grinding
(631) 758-8264
269 West Ave
Patchogue, NY
Biltmore Contrctng Inc
(516) 256-2030
331 W Merrick Rd
Valley Stream, NY
Wojcik John L
(518) 237-4364
1 2nd St
Cohoes, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer

Related Articles
- Green Construction Patchogue NY
Sustainable building practices are gaining acceptance in the competitive world of concrete construction. The editors of Concrete Construction and The Concrete Producer have created a new award program to recognize the concrete community's innovative contributions to green building.