Incorrect Testing Practices Ogdensburg NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Ogdensburg. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Coots Poured Walls
(607) 776-3903
Telegraph Rd
Bath, NY
Ebancardy Construction
(718) 329-0824
2239 Webster Ave
Bronx, NY
Social Concrete Inc
(631) 345-3748
131 Mill Rd
Yaphank, NY
Mime Constr Corp
(914) 793-2728
90 Candlewood Dr
Yonkers, NY
Union Concrete Construction Corp
(716) 759-6125
New York State Thrwy
Clarence, NY
Dean Concrete
(315) 394-0692
57 Sparrowhawk Point Dr
Ogdensburg, NY
M & M Industries Llc
(845) 236-3070
384 Bingham Rd
Marlboro, NY
Shotcrete Service
(716) 569-3045
50 White Dr
Frewsburg, NY
Tsws Stucco
(516) 216-1171
280 Meacham Ave
Elmont, NY
Ace Concrete & Asphalt Co
(718) 665-4004
655 Courtlandt Ave
Bronx, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer