Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in New Windsor. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Allegro Landscaping
845-294-8119
32 Parkway
Goshen, NY
N E C NORTH EASTERN CONTRACTING
845-298-4400
1127 RT 9
wappinger falls, NY
Ohioville Acres
(845) 255-4554
26 Cook Lane
Gardiner, NY
M. J. Posner Construction Co., Inc.
(845) 255-7187
161 State Route 208
New Paltz, NY
Living Art Landscapes Inc.
(845) 691-8992
428 N. Riverside Rd
Highland, NY
Carriage Park
845-294-3400
102 Cantor Court
Goshen, NY
Pioneer Blacktopping
(123) 456-7890
10 North Street
Wappingers Falls, NY
M. J. Posner Construction Co., Inc.
(845) 255-7187
161 State Route 208
New Paltz, NY
Trapps Builders Inc.
(845) 895-1782
199 Denniston Rd.
Wallkill, NY
C.T. Male Associates, P.C.
(845) 691-7234
652 Route 299, Suite 204B
Highland, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...