Incorrect Testing Practices Horseheads NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Horseheads. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Davies John M
(607) 733-8781
289 Ridge Rd
Horseheads, NY
F J Concrete Corp
(631) 234-0164
19 Hawthorne Ave
Central Islip, NY
Presti Ready Mix Concrete Inc
(516) 378-6006
210 E Merrick Rd
Freeport, NY
USA Concrete
(845) 361-9828

Middletown, NY
F & M Concrete Corp
(845) 352-9019
10 Hoffman St
Spring Valley, NY
Cystal Valley Excavation/Mulch/Gravel
607-765-8124
20 River Road
Corning, NY
Kbc Concrete & Masonry Foundations
(607) 739-3881
63 Colonial Dr
Horseheads, NY
A & A Enterprises Inc
(631) 580-2725
1087 Terry Rd
Ronkonkoma, NY
Coretech Concrete Cutting
(845) 783-1850

Monroe, NY
Ferrucci Nunzio
(716) 893-6122
42 Lackawanna Ave
Sloan, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer