Incorrect Testing Practices Ballston Spa NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Ballston Spa. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Advanced Environmental Associates
(518)522-4406
2877 Rt.9
Malta, NY
Ethos Homes, LLC
518-275-5731
20 Jordan Ln
Glenville, NY
Caldas Concrete Co Inc
(845) 361-3700
201 Howell St
Pine Bush, NY
Coon Lawrence D & Son Inc Genl Contr
(518) 392-2558
136 Soller Heights Rd
Ghent, NY
Ideal Concrete Inc
(716) 893-6122
42 Lackawanna Ave
Sloan, NY
Residential One, LLC
518-383-3199
207 Riverview Road
Rexford, NY
Aquaseal USA
(866)788-9283
117 Vosburgh Road
mechanicville, NY
Tucci Construction Inc
(607) 773-0330
PO Box 429
Binghamton, NY
De Vincentis G & Son Constr Co
(607) 723-9971
7 Belden St
Binghamton, NY
Buchinsky Joseph Concrete
(607) 797-5116

Johnson City, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer