Incorrect Testing Practices Amsterdam NY

Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite in Amsterdam. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.

Local Companies

Advanced Environmental Associates
(518)522-4406
2877 Rt.9
Malta, NY
Form-It Construction Llc
(518) 842-7246

Amsterdam, NY
Extreme Concrete Designs
(631) 331-1665
6 Enterprise Dr
East Setauket, NY
P J Mullarkey Contracting
(718) 458-1234
3825 56th St
Woodside, NY
Sea Crest Construction Corp
(516) 868-3000
157 Albany Ave
Freeport, NY
Residential One, LLC
518-383-3199
207 Riverview Road
Rexford, NY
Ethos Homes, LLC
518-275-5731
20 Jordan Ln
Glenville, NY
Nelson Todd R Masonry Llc
(716) 488-2611

Jamestown, NY
Design Concrete Corp
(631) 732-8076
460 9Granny Rd
Medford, NY
Atlas Transit Mix Corp
(718) 523-3000
9511 147th Pl
Jamaica, NY

Source: THE CONCRETE PRODUCER/CONCRETE JOURNAL MAGAZINE
Publication date: November 1, 1998

By No Author

Abstract:

Erroneous results from improper testing can cause unnecessary rejection of good- quality concrete. Train your drivers to recognize some of the more common testing errors. This article is based on information presented in Down the Chute, the publication of Florida Independent Concrete and Associated Products Inc.The problem isn't confined to strength tests. Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.Some improper practices are:

  • Excessive prewetting, leaving surplus water in the container
  • Sampling from the form into which the concrete has been placed
  • Failure to remix the concrete sample in the sample container before starting the tests
  • Failure to use an aggregate correction factor
  • Use of the pressure meter to measure air content
  • Failure to firmly support the base plate
  • Base plate not large enough, allowing high-slump concrete to spill over the edge of the plate
  • Base not level
  • Dampening the slump cone and base leaving a puddle of water on the base
  • Measuring the difference between the top of the cone and the highest or lowest point on the slumped specimen
  • Fai...

Click here to read full article from The Concrete Producer