Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration in Massapequa Park.

Local Companies

SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Malatesta Paladino Inc
(718) 523-5656
13919 109th Ave
Jamaica, NY
Franklin Stucco Of Jamaica Inc
(718) 523-0099
14815 Liberty Ave
Jamaica, NY
Bixby Brink Landscape Contractors
(631) 673-7650
16 Gloria Ln
Huntington, NY
Prima Plastering Inc
(631) 427-8699
77 Soundview Rd
Huntington, NY
Begolli Brother Construction and Restoration
(516) 476-6166
134 maple avenue
westbury, NY
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY

Provided By:

Source: Masonry Construction
Publication date: April 1, 1992

By John A. Koski

Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration. Grout vibrators achieve their vibratory motion by means of an eccentric in the head. The head is connected by a flexible shaft to a power source. The head, shaft, and power source are the three main components of a grout vibrator.

POWER SOURCE

Most grout vibrators are powered by a gasoline engine or electric motor. Electric vibrators have an advantage in that they are compact, lightweight, and require little maintenance. Vibrators powered by gasoline engines are ideal for projects whereelectricity is not available.

SHAFT LENGTH

The shaft transfers power from the engine or motor to the head. To determine the best shaft length for a job, first determine the height of the lift. Add to this 1 foot for succeeding lifts. Finally add 4 feet so that the vibrator operator will be able to work comfortably from a standing position.

HEAD DIAMETER

The diameter of the head must be small enough to fit into the limited space found in the cores of masonry units and in the restricted spaces in cavity walls.

DESIGN CONSIDERATIONS

A grout vibrator should be rugged in design so that it can withstand rough handling.

Click here to read full article from Masonry Construction

Related Articles
- Eliminating Swirls in Precast Panels Massapequa Park NY
What can we do to eliminate swirls in precast panels? Sid Freedman of the Precast/Prestressed Concrete Institute says such swirls are signs of segregation caused by the placing method. Read on to know more.
- Form-Release Agents Massapequa Park NY
- Growing Your Business Massapequa Park NY
- Green Home Improvement Products Massapequa Park NY
- Forklift Maintenance Tips Massapequa Park NY
- Grout Pumps Massapequa Park NY