How to Choose a Grout Vibrator Hicksville NY

Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration in Hicksville.

Local Companies

SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Franklin Stucco Of Jamaica Inc
(718) 523-0099
14815 Liberty Ave
Jamaica, NY
Bosco & Sons Mason Contracting
(631) 385-9107
1036 Park Ave
Huntington, NY
Anastasio Inc
(631) 499-1777
1633 E Jericho Tpke
Huntington, NY
SLR Industries Inc.
631 893 3934
411 Broadway
West Babylon, NY
Hatiya Contracting Inc
718-395-7744
9322 74th Place
Woodhaven, NY
Rapid Masonry Restoration
(718) 424-8304
7906 37th Ave
Jackson Heights, NY
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
Fort Hill Landscape And Design Inc
(631) 271-8651
151 New York Ave
Huntington, NY
Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY

Provided By:

Source: Masonry Construction
Publication date: April 1, 1992

By John A. Koski

Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration. Grout vibrators achieve their vibratory motion by means of an eccentric in the head. The head is connected by a flexible shaft to a power source. The head, shaft, and power source are the three main components of a grout vibrator.

POWER SOURCE

Most grout vibrators are powered by a gasoline engine or electric motor. Electric vibrators have an advantage in that they are compact, lightweight, and require little maintenance. Vibrators powered by gasoline engines are ideal for projects whereelectricity is not available.

SHAFT LENGTH

The shaft transfers power from the engine or motor to the head. To determine the best shaft length for a job, first determine the height of the lift. Add to this 1 foot for succeeding lifts. Finally add 4 feet so that the vibrator operator will be able to work comfortably from a standing position.

HEAD DIAMETER

The diameter of the head must be small enough to fit into the limited space found in the cores of masonry units and in the restricted spaces in cavity walls.

DESIGN CONSIDERATIONS

A grout vibrator should be rugged in design so that it can withstand rough handling.

Click here to read full article from Masonry Construction

Related Articles
- Form-Release Agents Hicksville NY
Form-release agents or form oils represent only a small fraction of the cost of a manufactured concrete item, but they have a big influence on the quality and appearance of the concrete surface.
- Forklift Maintenance Tips Hicksville NY
- Grout Pumps Hicksville NY
- Growing Your Business Hicksville NY
- Eliminating Swirls in Precast Panels Hicksville NY
- Green Home Improvement Products Hicksville NY