Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration in Floral Park.

Local Companies

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
Mr B Home Repairs
(718) 206-4900
10640 Guy R Brewer Blvd
Jamaica, NY
Bixby Brink Landscape Contractors
(631) 673-7650
16 Gloria Ln
Huntington, NY
Academic Stone Setters Inc
(718) 463-7395
2907 119th St
Flushing, NY
Begolli Brother Construction and Restoration
(516) 476-6166
134 maple avenue
westbury, NY
Ugolini Elio Mason Contractor
(201) 433-4304
213 Harrison Ave
Jersey City, NJ
Samson Stone Co Inc
(201) 656-2417
1000 Newark Ave
Jersey City, NJ
Cotumaccio Luigi Masonry Contrctng Co
(718) 776-2661
9071 198th St
Jamaica, NY
Agl Land Design Inc
(631) 673-2854
19 Duncan Ln
Huntington, NY

Provided By:

Source: Masonry Construction
Publication date: April 1, 1992

By John A. Koski

Using a puddling stick to consolidate grout is no longer acceptable in most building codes. Changing codes now require that grout pours greater than 12 inches be both consolidated and reconsolidated by mechanical vibration. Grout vibrators achieve their vibratory motion by means of an eccentric in the head. The head is connected by a flexible shaft to a power source. The head, shaft, and power source are the three main components of a grout vibrator.

POWER SOURCE

Most grout vibrators are powered by a gasoline engine or electric motor. Electric vibrators have an advantage in that they are compact, lightweight, and require little maintenance. Vibrators powered by gasoline engines are ideal for projects whereelectricity is not available.

SHAFT LENGTH

The shaft transfers power from the engine or motor to the head. To determine the best shaft length for a job, first determine the height of the lift. Add to this 1 foot for succeeding lifts. Finally add 4 feet so that the vibrator operator will be able to work comfortably from a standing position.

HEAD DIAMETER

The diameter of the head must be small enough to fit into the limited space found in the cores of masonry units and in the restricted spaces in cavity walls.

DESIGN CONSIDERATIONS

A grout vibrator should be rugged in design so that it can withstand rough handling.

Click here to read full article from Masonry Construction

Related Articles
- Form-Release Agents Floral Park NY
Form-release agents or form oils represent only a small fraction of the cost of a manufactured concrete item, but they have a big influence on the quality and appearance of the concrete surface.
- Green Home Improvement Products Floral Park NY
- Growing Your Business Floral Park NY
- Grout Pumps Floral Park NY
- Eliminating Swirls in Precast Panels Floral Park NY
- Forklift Maintenance Tips Floral Park NY