How Masonry Buildings Resist Earthquakes Watervliet NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Watervliet are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Rusty Johnson Masonary Inc
(315) 482-7632
23284 County Route 3
La Fargeville, NY
Gonser Construction Inc
(716) 627-4547
5156 Lake Shore Rd
Hamburg, NY
Mascorp Inc
(315) 431-9624
6729 Commerce Blvd
Syracuse, NY
Conmas Inc
(607) 722-0041
19 Alice St
Binghamton, NY
Artusa & Artusa Construction Co
(631) 224-4029
86 Craig Rd
Islip Terrace, NY
Rock-N-Country Stone Mason
(607) 746-7460

Delhi, NY
City View Masonry Corp
(718) 894-0450
5817 59th Dr
Maspeth, NY
Abelcraft of Westchester Corp
(718) 405-9309
4653 White Plains Rd
Bronx, NY
Mughal Waterprooofing & Masonry Inc
(718) 856-6889
692 Coney Island Ave
Brooklyn, NY
The Masonry Worker Inc
(315) 829-5070

Vernon, NY

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Flashing at Sills Watervliet NY
Sill flashing controls water that penetrates through the masonry sill and helps control water penetrating the perimeter sealant joint around the windows. The sill flashing will prevent water from saturating the top of the masonry beneath the sill.
- Hand-Held Power Saws Watervliet NY
- Grout Pumps Watervliet NY
- Galvanized Wall Ties Watervliet NY
- High Cement Content Problems Watervliet NY
- Galvanized Wall Ties Watervliet NY
- Inner Corner at Base of Wall Watervliet NY
- Graphisoft EcoDesigner Watervliet NY
- Flashing Factors Watervliet NY
- Flue Liners for Masonry Chimneys Watervliet NY