How Masonry Buildings Resist Earthquakes Tarrytown NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Tarrytown are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Window Designs by Suzi
(914) 636-6859
23 Stephenson Blvd.
New Rochelle, NY
ADG Construction LLc.
(201) 446-9491
307 Dorothy Street
Fair Lawn, NJ
Wildermuth Tom Masonry
(518) 392-0795

Ghent, NY
Glen Masonry Constr Co Inc
(631) 382-9795
22 Lawrence Ave Ste 104
Smithtown, NY
Matell Contrctng Co Inc
(718) 824-1444
2635 Roberts Ave
Bronx, NY
KJ Construction
(646) 302-2481
3536 Bronxwood Avenue
Bronx, NY
911 Restoration
201-646-0055
320 Washington Ave
Hackensack, NY
Rockhard Masonry
(631) 924-3512

Middle Island, NY
Kurabo Indusries Ltd
(212) 355-2512

New York, NY
Koehler F W & Sons
(631) 266-5464
71 Carolyn Blvd
Farmingdale, NY
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.