How Masonry Buildings Resist Earthquakes Rye NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Rye are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

KJ Construction
(646) 302-2481
3536 Bronxwood Avenue
Bronx, NY
Window Designs by Suzi
(914) 636-6859
23 Stephenson Blvd.
New Rochelle, NY
911 Restoration
201-646-0055
320 Washington Ave
Hackensack, NY
O'hara's
(845) 634-5299

New City, NY
Ryan Mike Construction Co
(315) 689-6254
109 South St
Elbridge, NY
Monroe Fuchs DBA Charles Contracting
(212) 249-0190
444 E 82nd ST
New York, NY
Remy Builders
(718) 545-8960
26-36 18th Street
Long Island City, NY
nelson construction
516-881-0149
35-07-105 st
queens, NY
KS Construction and Kitchen Cabinets
(917) 864-2670
19541 Jamaica Avenue
Hollis, NY
Morris Restoration Llc
(716) 894-0102
40 Appenheimer Ave
Buffalo, NY
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Flue Liners for Masonry Chimneys Rye NY
Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.
- Inner Corner at Base of Wall Rye NY
- Grout Pumps Rye NY
- Galvanized Wall Ties Rye NY
- Hand-Held Power Saws Rye NY
- Flashing Factors Rye NY
- High Cement Content Problems Rye NY
- Graphisoft EcoDesigner Rye NY
- Flashing at Sills Rye NY
- Galvanized Wall Ties Rye NY