Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Riverhead are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Arcade Contracting & Restoration Inc
(718) 596-4030
615 Degraw St
Brooklyn, NY
Nethercott P W Inc
(914) 939-2383
433 W William St
Port Chester, NY
Heady Kenneth Contractor
(845) 226-8589
Cottontail Ln
Hopewell Junction, NY
Atomic Brick-Interlocking Paving
(631) 261-0554
16 Hasty Ln
Greenlawn, NY
Colonial Masonry Corp
(212) 477-5910
215 Park Ave S Ste 2010
New York, NY
Mjr Stoneworks
(518) 329-5595

Ancramdale, NY
Austin Don Masonry
(315) 592-5278
54 Wood Ridge Ln
Fulton, NY
Will & Will General Contractors
(716) 433-4304
6035 S Transit Rd
Lockport, NY
Long Island Pool Scapes
(631) 698-8873
2 Avalon Ct
Ronkonkoma, NY
Fratelli Constr Corp
(631) 207-9164
76 Middle Island Ave
Medford, NY

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Flue Liners for Masonry Chimneys Riverhead NY
Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.
- Inner Corner at Base of Wall Riverhead NY
- Galvanized Wall Ties Riverhead NY
- Galvanized Wall Ties Riverhead NY
- Graphisoft EcoDesigner Riverhead NY
- Flashing at Sills Riverhead NY
- High Cement Content Problems Riverhead NY
- Hand-Held Power Saws Riverhead NY
- Flashing Factors Riverhead NY
- Grout Pumps Riverhead NY