How Masonry Buildings Resist Earthquakes Malone NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Malone are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Austin Don Masonry
(315) 592-5278
54 Wood Ridge Ln
Fulton, NY
Will & Will General Contractors
(716) 433-4304
6035 S Transit Rd
Lockport, NY
Long Island Pool Scapes
(631) 698-8873
2 Avalon Ct
Ronkonkoma, NY
Fratelli Constr Corp
(631) 207-9164
76 Middle Island Ave
Medford, NY
Darcom Inc
(516) 872-3798
49 Dubois Ave
Valley Stream, NY
Arcade Contracting & Restoration Inc
(718) 596-4030
615 Degraw St
Brooklyn, NY
Nethercott P W Inc
(914) 939-2383
433 W William St
Port Chester, NY
Heady Kenneth Contractor
(845) 226-8589
Cottontail Ln
Hopewell Junction, NY
Atomic Brick-Interlocking Paving
(631) 261-0554
16 Hasty Ln
Greenlawn, NY
Colonial Masonry Corp
(212) 477-5910
215 Park Ave S Ste 2010
New York, NY

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Hand-Held Power Saws Malone NY
The WSR 1400-PE reciprocating saw features a smart power system that maintains blade speed under load and reduces cutting time. The saw is ergonomically designed with a vibration control, front hand grip, comfort side handle, and keyless blade clamp.
- Flashing at Sills Malone NY
- Inner Corner at Base of Wall Malone NY
- Galvanized Wall Ties Malone NY
- Graphisoft EcoDesigner Malone NY
- Flashing Factors Malone NY
- Grout Pumps Malone NY
- High Cement Content Problems Malone NY
- Galvanized Wall Ties Malone NY
- Flue Liners for Masonry Chimneys Malone NY