How Masonry Buildings Resist Earthquakes Great Neck NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Great Neck are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

DB CONSTRUCTION
(347) 365-8284
592 BUSHWICK AVE
Brooklyn, NY
911 Restoration
201-646-0055
320 Washington Ave
Hackensack, NY
AJ NYC CONSTRUCTION CORP
(917) 470-0009
2080 EAST 61st ST
Brooklyn, NY
Affordable Homes General Construction LLC
(718) 713-2446
511 Chauncey Street
Brooklyn, NY
Drywall & Taping Corporation
(516) 256-0121
54 Reade St
Long Island, NY
Atlas Plaster and Drywall
(212) 402-5300
66 W 38th St
New York, NY
X Builders Inc
347-952-1776
9928 62nd drive
Rego Park, NY
HomeExcellence USA
1-888-896-7950
605 Water street
New York, NY
KS Construction and Kitchen Cabinets
(917) 864-2670
19541 Jamaica Avenue
Hollis, NY
NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Great Neck NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.
- Grout Pumps Great Neck NY
- High Cement Content Problems Great Neck NY
- Hand-Held Power Saws Great Neck NY
- Galvanized Wall Ties Great Neck NY
- Galvanized Wall Ties Great Neck NY
- Flashing at Sills Great Neck NY
- Graphisoft EcoDesigner Great Neck NY
- Flashing Factors Great Neck NY
- Flue Liners for Masonry Chimneys Great Neck NY