How Masonry Buildings Resist Earthquakes Fresh Meadows NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Fresh Meadows are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Remy Builders
(718) 545-8960
26-36 18th Street
Long Island City, NY
X Builders Inc
347-952-1776
9928 62nd drive
Rego Park, NY
HomeExcellence USA
1-888-896-7950
605 Water street
New York, NY
KS Construction and Kitchen Cabinets
(917) 864-2670
19541 Jamaica Avenue
Hollis, NY
NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Finesse Interiors Drywall Incorporated
(212) 633-0123
80 8th Ave
New York, NY
DB CONSTRUCTION
(347) 365-8284
592 BUSHWICK AVE
Brooklyn, NY
911 Restoration
201-646-0055
320 Washington Ave
Hackensack, NY
AJ NYC CONSTRUCTION CORP
(917) 470-0009
2080 EAST 61st ST
Brooklyn, NY
Affordable Homes General Construction LLC
(718) 713-2446
511 Chauncey Street
Brooklyn, NY
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Flue Liners for Masonry Chimneys Fresh Meadows NY
Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.
- Galvanized Wall Ties Fresh Meadows NY
- Inner Corner at Base of Wall Fresh Meadows NY
- Hand-Held Power Saws Fresh Meadows NY
- Graphisoft EcoDesigner Fresh Meadows NY
- Flashing at Sills Fresh Meadows NY
- Flashing Factors Fresh Meadows NY
- High Cement Content Problems Fresh Meadows NY
- Grout Pumps Fresh Meadows NY
- Galvanized Wall Ties Fresh Meadows NY