How Masonry Buildings Resist Earthquakes Fredonia NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Fredonia are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Gentile Peter Mason Contrctng
(516) 932-5611
134 Broadway
Bethpage, NY
McGowan James
(845) 339-0329
5 Railroad Ave
Kingston, NY
Zarrelli Dante Mason Contractor
(518) 725-4408

Gloversville, NY
Rock-N-Country Stone Mason
(607) 746-7460

Delhi, NY
City View Masonry Corp
(718) 894-0450
5817 59th Dr
Maspeth, NY
Hrw Construction Corp
(212) 829-9014
39 E 63rd St
New York, NY
Town Masonry Corp
(914) 779-5100
711 S Columbus Ave
Mount Vernon, NY
R P Prudente Contracting Corp
(516) 333-1777
496 Grand Blvd
Westbury, NY
New York Design General Contractors Inc
(718) 966-2447
48 Marne Ave
Staten Island, NY
Rusty Johnson Masonary Inc
(315) 482-7632
23284 County Route 3
La Fargeville, NY

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Inner Corner at Base of Wall Fredonia NY
The concrete masonry can be connected to the corner column with a debonded shear anchor. This type of anchor resists out-of-plane (but not in-plane) shear forces and permits movement between the steel column and concrete masonry.