How Masonry Buildings Resist Earthquakes Farmingdale NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in Farmingdale are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

KS Construction and Kitchen Cabinets
(917) 864-2670
19541 Jamaica Avenue
Hollis, NY
Koehler F W & Sons
(631) 266-5464
71 Carolyn Blvd
Farmingdale, NY
Koehler F W & Sons
(631) 694-4720
108 Allen Blvd
Farmingdale, NY
A Leto Asphalt & Consulting
(518) 887-5569

Rotterdam Junction, NY
Iovino Mason Contractor
(516) 334-4636
50 Swalm St
Westbury, NY
Manhattan Contracting Corp.
(631) 584-5155
34 East Main Street
Smithtown, NY
NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Brookfield Maintenance
(631) 789-3955
23 Grand Ave
Farmingdale, NY
Van Alphen Brothers Inc
(718) 981-7518
705 Van Duzer St
Staten Island, NY
Barnes Construction
(716) 665-4332
65 E Main St
Falconer, NY
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction

Related Articles
- Flue Liners for Masonry Chimneys Farmingdale NY
Building codes require that residential masonry chimneys with walls thinner than 8 inches (nominal) be lined with a fire clay flue lining, fire clay brick, or a material that resists corrosion, softening, and cracking from flue gases as hot as 1,800 degrees Fahrenheit.
- Flashing Factors Farmingdale NY
- Grout Pumps Farmingdale NY
- Flashing at Sills Farmingdale NY
- Galvanized Wall Ties Farmingdale NY
- High Cement Content Problems Farmingdale NY
- Galvanized Wall Ties Farmingdale NY
- Hand-Held Power Saws Farmingdale NY
- Inner Corner at Base of Wall Farmingdale NY
- Graphisoft EcoDesigner Farmingdale NY