How Masonry Buildings Resist Earthquakes East Meadow NY

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings in East Meadow are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

Local Companies

Remy Builders
(718) 545-8960
26-36 18th Street
Long Island City, NY
nelson construction
516-881-0149
35-07-105 st
queens, NY
KS Construction and Kitchen Cabinets
(917) 864-2670
19541 Jamaica Avenue
Hollis, NY
NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Juarez & Son's Masonry
(631) 348-7144
3 Leaf Ave
Central Islip, NY
KJ Construction
(646) 302-2481
3536 Bronxwood Avenue
Bronx, NY
Window Designs by Suzi
(914) 636-6859
23 Stephenson Blvd.
New Rochelle, NY
X Builders Inc
347-952-1776
9928 62nd drive
Rego Park, NY
Affordable Homes General Construction LLC
(718) 713-2446
511 Chauncey Street
Brooklyn, NY
Pannella Contracting
(516) 783-6754
2750 Birch Ave
East Meadow, NY
Data Provided by:
  

Provided By:

Source: Masonry Construction
Publication date: January 1, 1990

By Richard E. Klingner

How vulnerable are masonry buildings to earthquakes? How can they be designed to resist earthquakes?

HOW MASONRY BUILDINGS RESPOND

Because masonry buildings usually have many structural wall elements, they tend to be stiff laterally. Because masonry buildings are stiff laterally, even moderate earthquakes can subject them to large shear loads at their base.

For a typical masonry building, these shear loads can be calculated in the following way: Base shear load= (building mass) x (earthquake ground acceleration) x (dynamic amplification factor).

MASONRY SEISMIC DESIGN

Though even moderate ground accelerations can subject masonry buildings to large shear loads, masonry buildings can still be designed to resist these loads. In general, the designer must estimate the lateral inertial forces acting on each element and provide for the transfer of these forces down to the foundation.

INELASTIC RESPONSE OF MASONRY BUILDINGS

A masonry building's earthquake resistance has been described here as a function of wall layout, wall area, and wall strength. These characteristics are often sufficient. Enough wall area can often be provided so that even during a strong earthquake the building's walls remain basically elastic, without any yielding of reinforcement. However, architectural constraints may limit the wall area that can be provided.

Click here to read full article from Masonry Construction