Home Siding Tips Suffern NY

After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.

Local Companies

Craig Custom Builders
144 Osceola Rd
Wayne, NJ
Paragon Installers, LLC
556 N. Route 17
Paramus, NJ
Gisolfi Peter Associates
(914)478-3677
566 Warburton Avenue
Hastings On Hudson, NY
G. Biloba Garden Environment Inc.
(845)353-3448
45 Lydecker
Nyack, NY
G & L Landscaping
(914)376-7461
37 Orchard
Yonkers, NY
Len Van Builders
31 Stalter Drive
Wayne, NJ
G&L and Sons Renovations
153 Young Ave.
Cedar Grove, NJ
Franzoso Contracting
33 Croton Point Ave.
Croton-on-Hudson, NY
Beitals Aquariuns Sales and Service
(845)735-2300
22 West Dexter Plaza
Pearl River, NY
Cortland Stone Corporation
(914)737-1070
1000 North Division Street
Peekskill, NY
Data Provided by:
  

Provided By:

Source: REPLACEMENT CONTRACTOR Magazine
Publication date: November 1, 2005

By Carl Sperry

A constant problem that contractors see in siding installations is improper flashing or, even worse, no flashing at all. Relying on caulk alone to keep water from leaking into homes is not a good practice. Whether you're talking about wood, fiber-cement, or vinyl siding, three areas in particular can prove problematic:

Above door and window headers.

After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose. Flashing has to be intact to do its job, which is to keep water from contact with the wall. That goes for the weather barrier as well. Run the weather barrier over the flashing so that water doesn't get behind it. You want water to run over, not under, the siding.

Inside corners.

Tough and tricky, because sometimes your weather barrier gets torn trying to fit it into corners at a 90-degree angle. A simple fix for this is bending flashing in an L-shape before installing it in the corner. Then, after flashing is installed, run weather barrier over the flashing to eliminate the worry of tearing the paper and getting a leak.

Roofs and walls.

Another overlooked detail is where roofs intersect walls. Relying on step flashing alone is usually not enough.