High Cement Content Problems Middle Village NY

Portland cement gives a mortar added durability, high early strength, a consistent hardening rate, and high compressive and bond strengths. However, mortar with excessively high cement contents can affect water permeability and durability of the masonry.

Local Companies

E C Hufnagel Landscaping Inc
(201) 869-5680
51 Broad Ave Apt 1
Fairview, NJ
Jetco Unlimited Exterior Building Restoration & Maintenance
(201) 798-3178
268 New York Ave
Jersey City, NJ
Jameson Mark
(201) 386-1500
Hoboken Area
Jersey City, NJ
Franklin Stucco Of Jamaica Inc
(718) 523-0099
14815 Liberty Ave
Jamaica, NY
Obama Inc
(718) 321-0380
13225 Maple Ave
Flushing, NY
Begolli Brother Construction and Restoration
(516) 476-6166
134 maple avenue
westbury, NY
Ugolini Elio Mason Contractor
(201) 433-4304
213 Harrison Ave
Jersey City, NJ
Willow Run Construction
(201) 659-7266
67 Pollock Ave
Jersey City, NJ
A La Marca Construction
(718) 526-7795
14402 91st Ave
Jamaica, NY
Kabinet King
(718) 291-5023
17605 Linden Blvd
Jamaica, NY

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: December 1, 1990


Portland cement gives a mortar added durability, high early strength, a consistent hardening rate, and high compressive and bond strengths. However, mortar with excessively high cement contents can affect water permeability and durability of the masonry. Water permeability is increased for three reasons. First, mortars with high cement content have greater shrinkage and more frequent shrinkage cracks. Shrinkage cracking often takes the form of evenly spaced vertical cracks in bed joints and evenly spaced horizontal cracks in head joints. The mortar may also separate or pull away from the body of the brick at the bond interface. Although high cement content mortar itself is less permeable, water can penetrate the shrinkage cracks. The second reason that high cement content mortars may increase water permeance is that these mortars are stiff and not easily workable. Because of this, good bond may not be achieved at the time of construction. Finally, the high strength (high cement content) mortars are hard (brittle) and don't easily accommodate movement of the masonry (due to environmental changes or foundation settlement) and therefore may result in cracking of the masonry wall. Cracks make the walls more susceptible to freeze-thaw deterioration even though hi...

Click here to read full article from Masonry Construction

Related Articles
- Incorrect Testing Practices Middle Village NY
Conducting other tests improperly can also cause rejection of in-spec concrete at the jobsite. Have your drivers learn the correct methods for sampling concrete, measuring slump and air content, and making and curing strength-test specimens in the field. They're your first line of defense against needlessly rejected loads of concrete.
- Home Siding Tips Middle Village NY
- Galvanized Wall Ties Middle Village NY
- Galvanized Wall Ties Middle Village NY
- Fibers for Permeability Middle Village NY
- Flashing in Siding Installations Middle Village NY
- Eliminating Swirls in Precast Panels Middle Village NY
- Flue Liners for Masonry Chimneys Middle Village NY
- Handling Siding Materials Middle Village NY
- Energy-Efficient Product Reviews Middle Village NY