Galvanized Wall Ties White Plains NY

Do wall ties need to be galvanized in solid masonry walls in White Plains? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

170 East End Ave Construction Llc
(212) 288-1114
534 E 88th St
New York, NY
Pantheon Industries
(212) 828-1823
1500 Lexington Avenue
New York, NY
Going Green Home Decor
201.488.8889
180 Main ST
Hackensack, NJ
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Siller Stairs
(347) 491-3833
18-12 130th Street
New York, NY
CEKInt.
(917) 477-8175---(917) 657-1389
600 West 115 Street
NYC, NY
A C Flooring NY Inc
914-231-6647
188 voss ave.
yonkers, NY
Mr. Handyman
914-461-3400
719 West Nyack Rd
West Nyack, NY
Durafford Construction & Waterproofing, Inc.
718-395-7668
General Contractor
E. Elmhurst, NY
Van Go General Contracting
(201) 387-9013
326 So. Washington Ave
Bergenfield, NJ
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate. The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age. Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips White Plains NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- Drape Wall and Cloak Wall White Plains NY
- Foolproof Layout Method Plans White Plains NY
- Fighting Fastener Corrosion White Plains NY
- High-Efficiency Products White Plains NY
- Flashing Factors White Plains NY
- Fan-Fold Foam Board White Plains NY
- Inner Corner at Base of Wall White Plains NY
- Galvanized Wall Ties White Plains NY
- How Masonry Buildings Resist Earthquakes White Plains NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details