Galvanized Wall Ties Smithtown NY

Do wall ties need to be galvanized in solid masonry walls in Smithtown? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Nancy Lovas Architect LLC
13 4Th St,
Norwalk, CT
V. Design Architects PLLC.
17 Rolling Hill Drive
Patchogue, NY
Robert O'Shea Architect
821 West Jericho Pike
Smithtown, NY
ADL III Architecture P.C.
24 Woodbine Avenue,Suite 1
Northport, NY
Legacy Builders and Remodelers
1363-8 Lincoln Ave
Holbrook, NY
PB Architects Inc.
277 Rowayton Ave,
Norwalk, CT
Hoschler Graziosi Architects, P.C.
123 South Street,Suite 206
Oyster Bay, NY
Art Of Form Architects P. L.
3939 New York Ave.
Seaford, NY
Carriage Hill Associates
299 Duffy Avenue
Hicksville, NY
Data Provided by:
    

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?
There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate.The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age.Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details