Galvanized Wall Ties Plainview NY

Do wall ties need to be galvanized in solid masonry walls in Plainview? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Culpen & Woods Architects, LLC
400 Main St Ste 300,
Stamford, CT
Avidan Karn Associates
57 South Road
Harrison, NY
Louis F. Baldino Architects
97 Pine Hollow Road
Oyster Bay, NY
JMK Architectural Service, P.C.
5 Todd Court
East Williston, NY
Alure Home Improvements
1999 Hempstead Turnpike
East Meadow, NY
Steven Mueller Architects, LLC
One West Elm Street
Greenwich, CT
Gordon E. Johnson Architect
23 N Wyndover Ln,
Stamford, CT
Norman Glavas Architects
(516)365-5111
162 Boulder Rd.
Manhasset, NY
Butt Otruba O'Conner Architects
(516)883-0880
1062 Northern Blvd.
Roslyn, NY
Data Provided by:
    

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?
There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate.The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age.Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Articles
- Fan-Fold Foam Board Plainview NY
Fan-fold foam board is widely marketed as an easy fix for improving the thermal performance and water resistance of walls when re-siding. But if not applied properly, this option could lead to moisture problems, according to leading building-science experts.
- Galvanized Wall Ties Plainview NY
- Foolproof Layout Method Plans Plainview NY
- Flashing Factors Plainview NY
- Fighting Fastener Corrosion Plainview NY
- How Masonry Buildings Resist Earthquakes Plainview NY
- Drape Wall and Cloak Wall Plainview NY