Galvanized Wall Ties New Windsor NY

Do wall ties need to be galvanized in solid masonry walls in New Windsor? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

SMA Architecture Planning Interiors, P.C
(914)271-2712
One Baltic Place
Croton-on-Hudson, NY
Stauros
(917)270-4183
90 Crystal Run Rd Ste 108
Middletown, NY
David A. Tetro, Architect P.C.
302 Lewis Avenue
Yorktown Heights, NY
Battoglia Lanza Architectural Group PC
209 Old Route #9, Suite #5
Fishkill, NY
Hibbs Architects
400 Market Industrial Park,Suite 12 Box 22
Wappingers Falls, NY
Berg Hennessy Olson Llp
(845)220-2070
50 Front Street
Newburgh, NY
Wheldon A. Abt, Architect
90 Crystal Run Road,Suite 108
Middletown, NY
Carmine A. Ciccone Architect P.C.
(845)692-5072
379 Crystal Run Road,P.O. BOX 4787
Middletown, NY
Highlands Architecture PLLC
1 Winterberry Rd
Beacon, NY
Minuta Architecture, PLLC
(845)565-0055
345 Windsor Highway,Suite 100
New Windsor, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?
There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate.The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age.Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Articles
- High-Efficiency Products New Windsor NY
This article talks about green products such as wooden wall. The WD66 wood folding glass wall system comes with krypton-filled Heat Mirror glazing, providing an energy-efficient solution for large openings. The glass has a 0.23 U-factor and an SHGC of 0.31.
- Drape Wall and Cloak Wall New Windsor NY
- Home Siding Tips New Windsor NY
- Flashing Factors New Windsor NY
- Foolproof Layout Method Plans New Windsor NY
- Fighting Fastener Corrosion New Windsor NY
- Fan-Fold Foam Board New Windsor NY
- Inner Corner at Base of Wall New Windsor NY
- How Masonry Buildings Resist Earthquakes New Windsor NY
- Galvanized Wall Ties New Windsor NY