Do wall ties need to be galvanized in solid masonry walls in Hempstead? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

x builders inc
347-952-1776
9031 171st st 2nd floor
jamaica, NY
Acrhitectural Metal & Glass Estimating Services LLC.
516-662-2875
96 Cypress Street
Floral Park, NY
DL Restoration & Builders Corp
718 275 3995
107-12 71st Road
Forest Hills, NY
Gotham Builders
800-444-4923
203- 20 Rocky Hill Road
Bayside, NY
Above Remodeling Corporation
(212) 939-7571
295 Madison Avenue
New York, NY
A PERFECT PAINTER AND WALLPAPER
(212) 262-1959
459,w 47st
new york, NY
jbs construction & waterproofing
(347) 583-5313
1149 white plains rd
bronx, NY
trinchese iron works and construction inc.
(718) 848-1954
3375 royal ave
oceanside, NY
LSB Construction, Inc.
(917) 338-4960
1590 York Avenue, Suite 3B
New York, NY
Uvs Construction
(718) 554-0426
Beach 74Th St
Arverne, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate. The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age. Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips Hempstead NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- High-Efficiency Products Hempstead NY
- Fan-Fold Foam Board Hempstead NY
- Galvanized Wall Ties Hempstead NY
- Drape Wall and Cloak Wall Hempstead NY
- Foolproof Layout Method Plans Hempstead NY
- How Masonry Buildings Resist Earthquakes Hempstead NY
- Flashing Factors Hempstead NY
- Inner Corner at Base of Wall Hempstead NY
- Fighting Fastener Corrosion Hempstead NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details