Galvanized Wall Ties Coram NY

Do wall ties need to be galvanized in solid masonry walls in Coram? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

James Edward Theiss Architects PC
150 Waterside Avenue
Northport, NY
Michael James Palladino, Inc.
1239 Route 25A
Stony Brook, NY
David Hodukavich Architect
241 Secatogue Lane
West Islip, NY
Peter E. Tokar Architect
3718 Sound Avenue
Riverhead, NY
Frank G. Relf, AIA, P.C.
545 East Jericho Turnpike
Huntington Station, NY
Legacy Builders and Remodelers
1363-8 Lincoln Ave
Holbrook, NY
Cashin Associates, P.C.
1200 Veterans Memorial Highway
Hauppauge, NY
Robert Higgins Architects
50 Hidden Acres Path
Wading River, NY
Vanguard Inspections, Inc.
16 Sequoia Drive
Coram, NY
Frank S. Smith Architect, PC
514 Larkfield Road
East Northport, NY
Data Provided by:
  

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?
There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate.The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age.Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction