Galvanized Wall Ties Bay Shore NY

Do wall ties need to be galvanized in solid masonry walls in Bay Shore? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?

Local Companies

Legacy Builders and Remodelers
1363-8 Lincoln Ave
Holbrook, NY
V. Design Architects PLLC.
17 Rolling Hill Drive
Patchogue, NY
David Hodukavich Architect
241 Secatogue Lane
West Islip, NY
Carriage Hill Associates
299 Duffy Avenue
Hicksville, NY
Precision Designs Architecture, P.C.
52 Commerce Drive
East Farmingdale, NY
Alure Home Improvements
1999 Hempstead Turnpike
East Meadow, NY
NEW YORK CITY BEST CONSTRUCTION CORP.
347-26-9950
25 BEECHWOOD PLACE
Massapequa Park, NJ
Art Of Form Architects P. L.
3939 New York Ave.
Seaford, NY
Good Samaritan Hospital Medical Center
1000 Montauk Highway
West Islip, NY
Joseph J. Chearmonte Architect
2752 Grand Avenue
Bellmore, NY
Data Provided by:
    

Provided By:

Source: MASONRY CONSTRUCTION MAGAZINE
Publication date: October 1, 1998

Do wall ties need to be galvanized in solid masonry walls? The steel used in concrete is typically not coated. Wouldn't solid masonry offer protection similar to that offered by concrete?
There is a substantial difference between the protection to steel offered by masonry and that offered by concrete. In concrete, the fluid cement paste completely covers the bars. In masonry, the steel is often dry-laid on the units and the mortar placed on the top. Therefore, the bars are not always encased completely in mortar. Sometimes there are voids along the bottom of the bars, which can allow condensation and moisture to accumulate.The corrosion potential of the steel is also affected by material porosity and diffusion rates of harmful ions (such as chlorides). Bare steel is protected initially by a passivating layer that forms in the highly alkaline environment of wet concrete or mortar. Carbonation will reduce the alkalinity of the mortar or concrete and eliminate this protection. Mortars, being more porous than concrete, will carbonate at greater rates. There is also greater potential for diffusion from chloride ions from acid cleaning or other sources. Depending on their concentration, chloride ions will eliminate the pacifying effect of the mortar. For these reasons, unprotected steel encased in mortar will have an increased corrosion potential at a young age.Requirements for concrete or mortar cover...

Click here to read full article from Masonry Construction

Related Articles
- Home Siding Tips Bay Shore NY
After installing window and door trim, either make flashing using a sheet metal brake or apply flashing pre-bent to the correct trim size. Nail your flashing to the wall, not to the trim, because if you put holes in the flashing, you've defeated its purpose.
- Inner Corner at Base of Wall Bay Shore NY
- High-Efficiency Products Bay Shore NY
- Foolproof Layout Method Plans Bay Shore NY
- How Masonry Buildings Resist Earthquakes Bay Shore NY
- Fighting Fastener Corrosion Bay Shore NY
- Fan-Fold Foam Board Bay Shore NY
- Drape Wall and Cloak Wall Bay Shore NY
- Flashing Factors Bay Shore NY
- Galvanized Wall Ties Bay Shore NY
Related Local Event
Long Island Building & Facility Maintenance Show
Dates: 5/5/09 - 5/8/20
Location: David S. Mack Sports & Exhibition Complex - Hofstra University
Hempstead, NY
View Details